PLASMA - LOW TEMPERATURE STERILIZER

Hospital & Laboratory Application

The Plasma Low Temperature Sterilizer CISA (as shown on the legend) according the regulations of the CSSD is installed in the clean area with pass through access of the sterile area.

The plasma machine operates based on sterilisation with hydrogen peroxide.

Peroxide has a high oxidising effect, when it enters into the sterilisation chamber in vacuum conditions and in the presence of an electromagnetic field, it reforms into free radicals, spreading over the instrument surfaces.

These active radicals kill bacteria and micro-organisms, even at low temperatures.

It is therefore effective on temperature sensitive materials or in any case on instruments which are not resistant to high temperatures.

The degree of vacuum reached by the machine also allows removing any remaining peroxide residuals at the end of the sterilisation,which would otherwise remain on.

WITHIN THE CSSD / WHERE YOU CAN FIND ME

The Sterile Processing Department (Central Supply, or Sterile Supply as it is also known), comprises that service within the hospital in which medical/surgical supplies and equipment, both sterile and nonsterile, are cleaned, prepared, processed, stored, and issued for patient care.

The Plasma Low Temperature Sterilizer CISA (as shown on the legend) according the regulations of the CSSD is installed in the clean area with pass through access of the sterile area.

MODEL P-420 SPS EASY

How It Works

The plasma machine operates based on sterilisation with hydrogen peroxide. Peroxide has a high oxidising effect, when it enters into the sterilisation chamber in vacuum conditions and in the presence of an electromagnetic field, it reforms into free radicals, spreading over the instrument surfaces. These active radicals kill bacteria and micro-organisms, even at low temperatures. It is therefore effective on temperature sensitive materials or in any case on instruments which are not resistant to high temperatures. The degree of vacuum reached by the machine also allows removing any remaining peroxide residuals at the end of the sterilisation,which would otherwise remain on the instruments.

ADVANTAGES OF THE PLASMA METHOD

The Plasma series offers optimal sterilisation results for a wide range of medical devices.

 

  • Low temperature sterilisation (45-50 °C)
  • Improved penetration and efficiency
  • Improved heat distribution
  • No toxic residue
  • Full and safe sterilisation
  • Lower operating costs
  • Lower maintenance costs
  • Designed to be easily moved (on wheels)
  • High sterilisation flexibility
  • Colour touch screen to monitor parameters
  • Integrated incubator for microbiological tests
  • Multi shot hydrogen peroxide cartridges

CLICK DOWNLOAD

THE CATALOG

HEADQUARTERS ITALY

Via Enrico Mattei snc

55100 Lucca, Italy

P. +39 0583 15381

F. +39 0583 1538127

d.vendite@cisagroup.it

export@cisagroup.it

BRASILE

Rua Dona Francisca, 8300 Distrito

Industrial Bloco I, Mòdulo 2

CEP 89239, 270 Joinville

SC Brasil

P. +55 47 3801 9090

cisa@cisabrasile.br

ASIA

190 Middle Road

#19-05 Fortune Centre

188979 Singapore

P. +65 6826 1065

M. +65 919 09122

asia.sales@cisagroup.net

MIDDLE EAST

P.o Box, 3692

11821 Amman, Jordan

P. +962 6 556 3091

P. +962 6 556 3092

F. +962 6 556 3093

middleeast.sales@cisagroup.net

COPYRIGHT © 2017  |  CISA production srl - Unipersonale

Via Enrico Mattei snc,  angolo Via la Viaccia, 55100 Lucca (LU) | Tel. +39 0583 15381 | PEC: cisaproductionsrl@legalmail.it

C.F./P.IVA / R.I. Lucca 12435741009 |  CCIAA: LU216451 | Capitale sociale: Euro € 3.000.000 i.v.

Privacy Policy